Main Controls for Aerial and Outriggers
are located at the Pump Panel Move Mouse over Controls to Identify
NOTE: PTO and Electrical MUST work for aerial operations,
EPU (Emergency Power Unit) can power hydraulics for
short periods
Rear controls should be used for outriggers
auxilliary ladder controls are at the base of the ladder
behind door (NOTE: NO SAFETY for these controls)
auxilliary outrigger controls are behind tilt-up door
behind top steps
NOTE: ALWAYS have ladder drain open
when retracting ladder
Auxilliary Ladder Controls
Electricity NOT reqiured BUT hydraulic pressure needed move mouse over control to identify its function
Primary Outrigger Controls move
mouse over switches to identify function
NOTE: these controls require electrical power, if missing
use aux
Auxilliary Outrigger Controls
(behind steps on rear of truck)
no electrical power required but hydraulics needed
note: use EPU if PTO no working,
activation required hard push in center of black rubber move mouse over control to identify function
NOTE: Other Set of Push Soleniods must be reached behind
these seen, must be pushed hard with a hard object in
the center of black rubber to activate
SAFETY
Climbing should be from 0 to 45 degrees
Climbing MUST not be higher than 75
degrees